CCT-AA

Borehole Measurement Centralizer / Caliper Tool

CCT-AA
Centralizer / Caliper Tool

CCT-AA.png

 

CCT-AA
Centralizer / Caliper
Presentation

CCT-AA Presentation.png

 

 

PART No: 10710 – 4602

DESCRIPTION

The four-arm CCT provides tool centralization and borehole diameter values.
 

SPECIFICATIONS

Parameters
English
Metric
Pressure
20,000 PSI
1,379 bar
Temperature
350° F
177° C
Weight
105 lbs
48 kg
Tool Length
7.52 ft
2.29 m
Transport Length
9.33 ft
2.84 m
Tool OD
          Housing Diameter
3.11 in
7.90 cm
          Expanded Bow String
16 in
40.64 cm
1 From end of top thread protector to end of bottom thread protector.
 

COMBINABLE WITH

The CCT is combinable with all TTI open hole tools. It may be placed anywhere below the Gamma Ray/Spectral Gamma Ray tools (GRT) and above the Phased Induction Tool (PIT).

REMARKS

The CCT is calibrated using a using a set of rings with inside diameters of 8" and 14". Typical application for the CCT is to run in combination with the Compensated Sonic Tool (CST).
 
For information on Parts, Test, Calibration and Accessory equipment available for the CCT-AA, contact your Tucker Technologies Technical Sales Representative

LOGGING PARAMETERS

Parameter
English
Metric
Vertical Resolution – Caliper
8 in
20.32 cm
Measurement Range:
Caliper (PDT)       3.625 in to 16 in (9.2 cm to 40.6 cm)
Maximum Logging Speed
120 ft/min
37 m/min
Repeatability
Caliper
 
±0.2 in, ±5.1 mm
Borehole Ranges:
Minimum
4.2 in
10.7 cm
Maximum
16 in
40.6 cm
 

BOREHOLE ENVIRONMENT

Open, cased, fluid- or air-filled holes.